8200 LENZE PDF

The mains task of vector frequency inverters is the electronic speed adjustment of three-phase AC motors. Together with a Lenze geared motor or a. Lenze. SHB Legal regulations. Identification Nameplate. CE- identification. Manufacturer. Identification. Lenze controllers are unambiguously. The frequency inverter vector produced by Lenze GmbH & Co KG is used to achieve electronic speed variation of AC motors.

Author: Zululkis Vudobar
Country: Dominica
Language: English (Spanish)
Genre: Health and Food
Published (Last): 23 October 2016
Pages: 101
PDF File Size: 6.83 Mb
ePub File Size: 20.58 Mb
ISBN: 985-8-32088-380-6
Downloads: 38861
Price: Free* [*Free Regsitration Required]
Uploader: Dukree

This is what the vector modular range of frequency inverters in the power range from 0. Faulty penze of control commands via AIF. Slave does not respond. Strong interference injections on the control cables Shield control cable. The keypad is plugged onto the front of the inverter and is also used for the status display, error diagnosis and, with integrated memory, to transfer parameters to other inverters.

Complete with everything you need for convenient operation, handling, diagnostics and communication. Check whether bus termination is available.

The Lenze 800 Drive vector frequency inverter — for standard applications The concept of the Lenze AC Drive frequency inverter is based on a modular system of components adjusted to each other.

And the vector series is of course certified in line with international standards. Via a bus module from a host system. Home Transdrive Contact About.

Installation costs are reduced using integrated filters optional. Sales and Product Support Ready to Help. Reliable Adjustable slip compensation balances load-related speed variations without costly speed feedback.

You may also like -  AEROCCINO PLUS MANUAL PDF

When operating with module on FIF: Call our sales and support. Via an operator module. Fan failure only motec Connect fan Check wiring.

Earth loops in the wiring.

AC Drive Lenze kW 1PH E82EVK2C

Pluggable function modules enable precisely tailored integration of the vector into the control and automation architecture of your machine or installation. The units are operated either via a plug-in Keypad XT control console or a PC in lehze with the convenient and free-of-charge Global Drive Control easy operating software. Controlled acceleration and deceleration using set acceleration and deceleration times.

Check bus load, reduce the baud rate, if necessary. The XT keypad is also used for status display, error diagnosis and, thanks to its integrated memory, for transferring settings to other inverters. Clear The XT keypad is also available for operation.

Troubleshooting and fault elimination. Assignment of inputs and outputs with standard functions. Communication-capable In communication with a host system, inverters can be incorporated using plug-on bus modules. Check wiring of the system bus. Troubleshooting and fault elimination, Error messages — Lenze motec frequency inverter 0. Controller has received to many faulty telegrams via the system bus lenzze has been disconnected from the bus.

The Lenze AC Drive frequency inverter. GDC lehze is free of charge and can be downloaded fromwww. A PTC resistor can be connected to protect the motor. Communication error in case of remote parameterisation via the system bus C configurable in C The right setpoint source for every requirement Via setpoint potentiometer to lennze control terminals.

The concept of the Lenze AC Drive lenzw inverter is based on a modular system of components adjusted to each other. Check system bus configuration.

You may also like -  WHITLEY STRIEBER MAJESTIC PDF

Lenze Vector Frequency Inverter Drive E82EVK2C | eBay

Fault messages on the keypad or in the parameter setting program Global Drive Control. Their compact dimensions of the 2. This series of Lenze AC Drive frequency inverter are characterised by simple operability and handling while also offering high levels of functionality. A clear menu structure and user-guided commissioning thanks to the Global Drive Control easy GDC easy parameterisation software makes rapid frequency converter parameter setting and diagnostics possible.

Communication monitoring time has been exceeded. Motor is not connected. Via digital frequency input. The keypad for the Lenze 82000 Drive provides a visual for the operating parameters and set parameters for the inverter.

Lenze 8200 Vector Frequency Inverter Drive E82EV751K2C

Amongst other things, parameters are set for: The modular structure allows you to optimise the inverters to your application, making cost-effective drive solutions possible while maintaining high performance levels. Communication abort between keypad and standard device.

Flexible The modular structure allows you to optimise the inverters to your application, making cost-effective drive solutions possible while maintaining high performance levels. Check plug connection of bus module. Via master voltage or master current to the control terminals. The integrated flying restart circuit means that a drive can be easily restarted when the shaft is still turning.

Begin typing your search term above and press enter to search. Press ESC to cancel.